eiXtra: published by NEMA Hot Topics
On the Hill/Around the Nation
International News
NEMAVoice
Monday, July 12, 2010
feature story
Building Better Batteries for Cars and Spacecrafts

NASA engineer Eric Darcy, left, and NREL engineer Kandler Smith get ready to test lithium-ion batteries for how well they can combat rare but potentially catastrophic thermal runaways.
NASA engineer Eric Darcy, left, and NREL engineer Kandler Smith get ready to test lithium-ion batteries for how well they can combat rare but potentially catastrophic thermal runaways.
A NASA engineer responsible for the batteries needed for spacewalks is now working at the Department of Energy (DOE) National Renewable Energy Laboratory (NREL) to help design safer lithium-ion battery packs for sky walkers and automobile drivers alike.

"We at NASA share the same challenges that DOE and NREL have in developing batteries for cars," said Eric Darcy, the battery group leader at the National Aeronautics and Space Administration's Johnson Space Center.

Whether it's "manned space travel or manned automobiles," the hurdles are the same, Mr. Darcy said. "Designing a safe, very large and lightweight battery pack for the confined space of manned vehicles is challenging."

In the future, battery-powered automobiles are expected to grab a big share of the market away from gasoline-fueled vehicles. Lithium-ion batteries are the technology of choice because of their high energy and power densities, said Ahmad Pesaran, energy storage group leader at NREL. But the batteries must be able to withstand abuses that could lead to thermal runaway, and potentially fire.

Thermal runaway can happen when an increase in temperature changes conditions in a way that leads to a further increase in temperature, a kind of feedback that can lead to catastrophe. The increase in temperature leads to an increase in the reaction rate, which leads to further increases in temperature. The disastrous release of methyl isocyanate gas from a Union Carbide plant in Bhopal, India, in 1984, was precipitated by a thermal runaway.

Researchers in NREL's Energy Storage Group are modeling and testing how well the risk of catastrophic thermal runaway can be mitigated in lithium-ion cell/battery designs.

NREL researchers expect the partnership to help them design next-generation battery packs for cars. Mr. Darcy's contributions are helping NREL's integrated network model to analyze the qualities of multi-cell battery pack systems and observe their responses to stress, NREL engineer Gi-Heon Kim said. "These kinds of model tools are crucial for car industries to properly perform thermal and safety assessment of their battery pack designs."

Inducing Shorts on Demand

This dime-sized coin made of aluminum and copper is used to induce short circuits in lithium-ion batteries. The ability to induce shorts on demand is crucial to finding out how hot a battery can get when it fails while in active use.  
This dime-sized coin made of aluminum and copper is used to induce short circuits in lithium-ion batteries. The ability to induce shorts on demand is crucial to finding out how hot a battery can get when it fails while in active use.
NREL and NASA engineers have invented specially designed small "coins" made of primarily aluminum and copper, that when implanted into lithium-ion cells will induce an internal short circuit on demand. The ability to accurately replicate internal shorts in battery cells is crucial to finding out how hot a battery can get when one of its cells fails because of a rare manufacturing defect. Those defects happen only about one time in one million in the field, but because of their catastrophic consequences, NASA and NREL need to lengthen those odds if lithium-ion batteries are to become the workhorses of space walks and automobile transportation.

NREL researchers have characterized the conditions under which an internal short circuit in a spacesuit battery can lead to a thermal runaway, which can cause a catastrophic explosion.

Safer Spacesuit Battery under Development

NASA has been developing a new spacesuit battery for three years, preparing for the time when the current short wet life battery packs of the shuttle-to-space-station era would require replacement.

The battery under study contains 80 laptop-sized lithium-ion cells, weighs about 15 pounds, and is about 11 inches long, 4 inches wide, and 5 inches deep. Laptop batteries can last three years if they're treated kindly, albeit they usually aren't, since most of the time they are kept fully charged and operate at high temperatures inside the cramped internal space of a laptop.

The new spacesuit battery will rest inside the backpack on the spacesuit, which packs a lot of thermal insulation, preventing it from getting very cold or very hot. So, even though it will be in the forbidding climes of outer space, it will experience less stress than a battery constantly being charged and discharged on planet Earth.

Auditing Performance of Lithium-ion Batteries

This prototype lithium-ion battery for automobiles has the advantage of being lighter and taking up far less room than the batteries now in hybrid cars.
This prototype lithium-ion battery for automobiles has the advantage of being lighter and taking up far less room than the batteries now in hybrid cars.
NASA needs to learn all it can about lithium-ion batteries because the nickel-hydrogen batteries now in use will expire in 2017.

Tiny latent defects imbedded in cells can be missed if testing isn't done under the strictest conditions. Those defects could cause an internal short circuit and a catastrophic event.

Internal short circuits are rare, but not unheard of. "You hear about these one-in-a-million recalls, when a laptop or a cell phone's battery defect causes it to go into flames," said Mr. Darcy.

Early this month, Mr. Darcy and Mr. Smith audited a lithium-ion manufacturing process. "They had some good processes and some weaknesses," Mr. Darcy said. "We made a long list of all those actions they ought to consider correcting to produce a better, safer product."

The lessons learned at the audits can be used by NREL to conduct similar audits on automobile battery manufacturers, Mr. Darcy said. "It's important that they do so, because if an incident occurred on a car battery, it would be a cancer to everyone who uses lithium-ion batteries," Mr. Darcy said. "Is mine going to have that same effect?

"They need to know why or why not. What measures can they take to minimize the risk of some kind of internal short inside the cell that can make it blow up?"

Photographs courtesy of NREL



We thank you for your cooperation in improving the quality of our materials.
Please contact Bill Green
at Communications@nema.org if you have any questions or suggestions related to eiXtra.


Hot Topics

07.12.10
100 LED Lamps for Sri Lankan Fishermen
Launched by the environment foundation Global Nature Fund, the project "Improving livelihoods of fishermen in Sri Lanka by introducing LED and compact fluorescent lamps for night fishing" aims to solve this problem.

[ top ]
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

On the Hill/Around the Nation

07.12.10
Electric Vehicle Infrastructure: House (HR 5442) and Senate (S 3442) legislation was introduced May 27 to advance deployment of 700,000 electric vehicles (EV) and related electrical infrastructure. The bills seeks to speed the use of plug-in EV by selecting 5 to 15 “deployment communities” through a competitive bidding process at the Energy Department with $10 billion tax and other federal incentives to building charging stations and other necessary infrastructure. The House bill also provides a $5 billion loan guarantee program for manufacturers of EV components and infrastructure charging. On July 22, NEMA will participate in the DOE workshop on EV infrastructure to discuss lessons learned from communities that have launched EV programs, including permitting and incentives. NEMA is advancing policies to create incentives to support deployment of new technologies and systems.

[ top ]
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

International News

07.12.10
Executive-Led Green ICT and Energy Efficiency Trade Mission
Dates: September 27–29, 2010
Location: Mexico City, Mexico
This is the first ever Green ICT & Energy Efficiency Trade Mission to Mexico City.

07.12.10
Latin American Energy Symposium
The key electrotechnology trade association and conformity assessment organizations in Mexico, CANAME and ANCE respectively, are hosting the fifth Latin American Energy Symposium August 4–5 in Mexico City. The agenda includes conferences on energy, installations, lighting, and control and distribution. Participants will include representatives from industrial sectors, producers, retailers, technicians, government officials, researchers, academics, and electrical and construction consultants of Mexico and Latin American countries. The sixth National Congress on NOM-001-SEDE, the Mexican electrical installation code, will also take place.

07.12.10
National Export Initiative to Increase Member Exports
Ex-Im Bank has issued what it calls “good news” about its ability to help small business exporters increase their sales beyond U.S. borders. In response to the difficulties small businesses face in accessing export financing, Ex-Im has changed its policy governing what constitutes eligible content of products financed by the Ex-Im Bank small business programs.

[ top ]
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • •


NEMAcastNEMA podcast for the electroindustry.

NEMAcast focuses on news, information, and opportunities in the electroindustry. Listen online at podcast.nema.org. NEMAcast has several channels, each with a special focus on different parts of the electroindustry. Check out "NEMA Technical Program Manager, Alex Boesenberg, Discusses Tubular (T8) Fluorescent Lamp Systems."


NEMAVoice

Industry News

Contracts

Mergers & Acquisitions

Personnel

[ Industry News Archives ]

NEMA News

  • NEMA Applauds Progress toward Energy Usage Information Standards
    A major step toward a standardized format for communicating actionable information on energy consumption to U.S. households has been achieved, according to the Smart Grid Interoperability Panel (SGIP), a public-private partnership initiated by the National Institute of Standards and Technology (NIST) to speed development of interoperability and cybersecurity standards for a nationwide "smart" electric power grid. 07/01/10

[ NEMA News Archives ]

[ top ]
Market Comments by Tom Robinson
Equity prices and industrial commodity prices rallied while bonds fell last week. No one really knows why, in the heat of the summer, last week should have been the chosen one, but it was. read more...


Upcoming Events:

Eicareers.org: The Electroindustry Career Portal - powered by NEMA
Job Title Company Name
Energy Project Manager EnerNOC, Inc.
Building/Electrical Inspector City of Franklin, TN
Click here to view ALL job Listings

Sponsored by
Sponsored by UL University a Certified PV System Installer

Looking to Become a Certified Photovoltaic (PV) System Installer?
UL University’s newly developed PV System Installer certification program aims to improve the safety and performance of PV systems through a more qualified workforce of licensed electricians.

If you are looking to become a Certified PV System Installer, this Personnel Certification program is designed to offer you an opportunity to set yourself apart with a credential focused on the critical knowledge and skills needed to install PV systems.

Contact UL University at 1.888.503.5536, email ULUniversity@us.ul.com or visit www.uluniversity.us/certification for training and certification exam dates, locations, pricing and to register.

To view this email on the web, go to http://www.nema.org/media/eiextra/briefs/20100712eiXtra.htm

Event Calendar
July 2010
S M T W T F S
1 2 3
4 5 6 7 8 9 10
11 12 13 14 15 16 17
18 19 20 21 22 23 24
25 26 27 28 29 30 31
.
Email
 

NEMA's 84th Annual Meeting: Illuminations Weekend, The Breakers, Palm Beach, FL - Nov 5-6, 2010

NEMA's ESPG 2009-2010

CSA Advertisement

IHS Advertisement

Subscribe to NEMAcast

NEMACurrents Blog

NEMA on YouTube.

© 2010 National Electrical Manufacturers Association. eiXtra is a biweekly e-newsletter for electroindustry professionals summarizing key manufacturer, standardization, and regulatory news. NEMA does not sell or release subscriber's personal information and will never willfully disclose individually identifiable information to any third party without first receiving your permission. Privacy policy.
Follow NEMA: Blog BlogPodcasts PodcastsTwitter TwitterYouTube YouTubeLinkedIn LinkedIn
Printer-friendly version | Unsubscribe