| [No Document Number] | Annular Space Protection of Openings Created by Penetrations of Tubular Steel Conduit, A Review of UL Special Service Investigation, File NC 546, Project 90NK11650 |
| [No Document Number] | Conduit-in-Casing Construction |
| [No Document Number] | Engineering Series Ratings: Is It Practical? |
| [No Document Number] | The Grounding System That Works-Steel Conduit (Electrical Metallic Tubing, Intermediate Metal Conduit and Galvanized Rigid) |
| [No Document Number] | Use of Temporary Covers on Panelboards |
| ANSI C119.4-2011 | American National Standard for Electric Connectors-Connectors for Use Between Aluminum-to-Aluminum and Aluminum-to-Copper Conductors Designed for Normal Operation at or Below 93°C and Copper-to-Copper |
| ANSI C119.5-2009 | American National Standard for Electric Connectors-Insulation-Piercing Connector Systems, Rated 600 V or Less (Low Voltage Aerial Bundled Cables and Insulated and Non-Insulated Line Wires) |
| ANSI C12.7-2005 | American National Standard for Requirements for Watthour Meter Sockets |
| ANSI C37.50-2012 | American National Standard for Switchgear-Low Voltage AC Power Circuit Breakers Used in Enclosures-Test Procedures |
| ANSI C37.51-2003 (R2010) | American National Standard for Switchgear-Metal-Enclosed Low Voltage AC Power Circuit Breaker Switchgear Assemblies-Conformance Test Procedures |
| ANSI C37.52-1974 (R1995, R2000) | American National Standard for Test Procedures for Low-Voltage AC Power Circuit Protectors Used in Enclosures |
| ANSI C37.54-2002 (R2010) | American National Standard for Indoor AC High Voltage Circuit Breakers Applied as Removable Elements in Metal-Enclosed Switchgear-Conformance Test Procedures |
| ANSI C37.55-2002 (R2010) | American National Standard for Switchgear-Medium Voltage Metal-Clad Assemblies-Conformance Test Procedures |
| ANSI C37.57-2003 (R2010) | American National Standard for Switchgear-Metal-Enclosed Interrupter Switchgear Assemblies-Conformance Testing |
| ANSI C37.58-2003 (R2010) | American National Standard for Switchgear-Indoor AC Medium Voltage Switches for Use in Metal-Enclosed Switchgear-Conformance Test Procedures |
| ANSI C80.1-2005 | American National Standard for Electric Rigid Steel Conduit (ERSC) |
| ANSI C80.3-2005 | American National Standard for Steel Electrical Metallic Tubing (EMT) |
| ANSI C80.5-2005 | American National Standard for Electrical Rigid Aluminum Conduit (ERAC) |
| ANSI C80.6-2005 | American National Standard for Intermediate Metal Conduit (EIMC) |
| ANSI/IEC 60529-2004 | American National Standard for Degrees of Protection Provided by Enclosures (IP Code) (Identical National Adoption) |
| ANSI/NEMA AB 3-2013 | Molded-Case Circuit Breakers and Their Application |
| ANSI/NEMA AB 4-2009 | Guidelines for Inspection and Preventive Maintenance of Molded-Case Circuit Breakers Used in Commercial and Industrial Applications |
| ANSI/NEMA FB 11-2000 | Plugs, Receptacles and Connectors of the Pin-and-Sleeve Type for Hazardous Locations |
| ANSI/NEMA FB 1-2012 | Fittings, Cast Metal Boxes and Conduit Bodies for Conduit, Electrical Metallic Tubing (EMT) and Cable |
| ANSI/NEMA KS 2-2013 | Distribution Equipment Switch Application Guide, A User's Reference |
| ANSI/NEMA OS 1-2008 (R2010) | Sheet-Steel Outlet Boxes, Device Boxes, Covers and Box Supports |
| ANSI/NEMA OS 2-2008 (R2010) | Nonmetallic Outlet Boxes, Device Boxes, Covers and Box Supports |
| ANSI/NEMA PB 1.1-2007 | General Instructions for Proper Installation, Operation and Maintenance of Panelboards Rated 600 V or Less |
| ANSI/NEMA PB 2.1-2007 | General Instructions for Proper Handling, Installation, Operation and Maintenance of Deadfront Distribution Switchboards Rated 600 V or Less |
| ANSI/NEMA WD 6-2002 (R2008) | Wiring Devices-Dimensional Specifications |
| NEMA 250-2008 | Enclosures for Electrical Equipment (1,000 V Maximum) |
| NEMA 410-2011 | Performance Testing for Lighting Controls and Switching Devices with Electronic Drivers and Discharge Ballasts |
| NEMA 5RN 2189-2003 | User Guide to Product Specifications for Metal Electrical Conduit and Tubing |
| NEMA BU 1.1-2005 (Spanish) | Instrucciones Generales para el Manejo, Instalacion, Operacion y Mantenimiento de Electroductos Hasta 600 V Nominales o Menos |
| NEMA BU 1.1-2010 | General Instructions for Handling, Installation, Operation and Maintenance of Busway Rated 600 V or Less |
| NEMA BU 1.2-2002 (R2008) | Application Information for Busway Rated 600 V or Less |
| NEMA FB 2.10-2012 | Selection and Installation Guidelines for Fittings for Use with Non-Flexible Electrical Metal Conduit or Tubing (Rigid Metal Conduit, Intermediate Metal Conduit and Electrical Metallic Tubing) |
| NEMA FB 2.20-2012 | Selection and Installation Guidelines for Fittings for Use with Flexible Electrical Conduit and Cable |
| NEMA FG 1-1993 | Fiberglass Cable Tray Systems |
| NEMA FU 1-2002 (R2007) | Low Voltage Cartridge Fuses |
| NEMA OS 3-2012 | Selection and Installation Guidelines for Electrical Outlet Boxes |
| NEMA PB 1.1-2002 (Spanish) | Instrucciones Generales para la Instalacion, Operacion y el Mantenimiento Correcto de Tableros de Alumbrado y Control Hasta 600 V Nominales o Menos |
| NEMA PB 1-2011 | Panelboards |
| NEMA PB 2.1-2002 (Spanish) | Instrucciones Generales para el Manejo, Instalacion, Operacion y Mantenimiento Correcto de Tableros de Distribucion de Frente Muerto Hasta 600 V Nominales o Menos |
| NEMA PB 2-2011 | Deadfront Distribution Switchboards |
| NEMA PRP 2-2009 | Solvent-Cementing Joints for PVC Rigid Nonmetallic Conduit, Duct and Fittings |
| NEMA PRP 4-2009 | Expansion Fittings for Polyvinyl Chloride (PVC) Rigid Nonmetallic Conduit |
| NEMA RN 1-2005 | Polyvinyl Chloride (PVC) Externally Coated Galvanized Rigid Steel Conduit and Intermediate Metal Conduit |
| NEMA RN 2-1997 (R2009) | Packaging of Master Bundles for Electrical Rigid Metal Conduit (ERMC)-Steel, Electrical Intermediate Metal Conduit (EIMC)-Steel, and Electrical Metallic Tubing (EMT)-Steel |
| NEMA RN 3-1991 (R2002) | Product Identification Numbers for Metallic Tubular Conduit Products for Use with Bar Coding and Electric Data Interchange (EDI) Applications |
| NEMA TC 13-2005 | Electrical Nonmetallic Tubing (ENT) |
| NEMA TC 14-2002 | Reinforced Thermosetting Resin Conduit (RTRC) and Fittings |
| NEMA TC 18-2004 | Packaging of Master Bundles for EPC-40 Polyvinyl Chloride (PVC) Conduit |
| NEMA TC 19-2001 (R2009) | Nonmetallic Riser U-Type Guards |
| NEMA TC 2-2003 | Electrical Polyvinyl Chloride (PVC) Tubing and Conduit |
| NEMA TC 3-2004 | Polyvinyl Chloride (PVC) Fittings for Use with Rigid PVC Conduit and Tubing |
| NEMA TC 6 & 8-2003 | Polyvinyl Chloride (PVC) Plastic Utilities for Underground Installations |
| NEMA TC 7-2005 | Smooth Wall Coilable Electrical Polyethylene Conduit |
| NEMA TC 9-2004 | Fittings for Polyvinyl Chloride (PVC) Plastic Utilities Duct for Underground Installation |
| NEMA TCB 3-2001 (R2009) | User's Manual for the Installation of Underground Corrugated Coilable Plastic Utility Duct (CCD) |
| NEMA VE 1-2009 | Metal Cable Tray Systems |
| NEMA VE 2-2006 | Cable Tray Installation Guidelines |
| NEMA WD 1-1999 (R2005, R2010) | General Color Requirements for Wiring Devices |